Schneider Power Factor Controller VPL12N


135,000.00

The latest Schneider Power Factor Controller VPL12N price in Pakistan is Rs. 135,000/- updated on September 9, 2026.

FEATURES:

  • Varplus logic 12 step
  • Power factor controller with automatic initialization & automatic detection

Metering type:

  • voltage U21, U32, U13, V1, V2, V3, on load
  • Apparent power S, S1, S2, S3, on load
  • Reactive power Q, Q1, Q2, Q3, on load
  • Active power P, P1, P2, P3, on load
  • Phase current 11, 12, 13 RMS on load
  • Temperature maximum
  • Power factor average over lifetime
  • Total current harmonic distribution THD (I)
  • Power factor and displacement PF(Signed, Four Quardrant)
Documents:

Schneider Power Factor Controller VPL12N Data Sheet.pdf

Computers Specs

ColorFront : dark grey (RAL 7016)

Display Specification

DisplayBacklit LCD
Display size56 x 25 mm
NameVarPlus Logic

Summary

Ambient Air Temperature for Operation-20…60°C
FunctionAutomatic initialisation
Automatic detection
Manual programming
Advanced programming (expert)
Any step sequence
Height144 mm
Weight0.6 kg
Depth58 mm
Output TypeControl relay : 0.2 A 110 V DC
Control relay : 1 A 48 V DC
Control relay : 2 A 400 V AC 50/60 Hz
Control relay : 1 A 24 V DC
Control relay : 5 A 250 V AC 50/60 Hz
Control relay : 5 A 120 V AC 50/60 Hz
Fan : 5 A 250 V AC 50/60 Hz
Fan : 1 A 48 V DC
Alarm relay : 5 A 250 V AC 50/60 Hz
Alarm relay : 1 A 48 V DC

HARDWARE FEATURES

Input TypeCurrent input CT…X/5 A and X/1 A
Insensitive to CT polarity
Insensitive to phase rotation polarity
Phase to neutral
Phase to phase
IP degree of protectionRear face : IP20
Front face : IP41
Mounting ModeFlush-mounted
Supply Voltage90…550 V AC
MountingIn cabinet

Type

product or component typePower factor controller

UC100

StandardsEN 61010-1
IEC 61000-6-2
IEC 61000-6-4
UL 61010-1
IEC 61326-1

General Specification

ConnectionCommunication protocol: Modbus interface: Rs. 485
`
Contacts12
Type ForMetering
Power factor and displacement PF (signed, four quadrant)
Total current harmonic distortion THD (I)
Power factor average over lifetime
Temperature maximum
Phase current I1, I2, I3 RMS on load
Active power P, P1, P2, P3 on load
Reactive power Q, Q1, Q2, Q3 on load
Apparent power S, S1, S2, S3 on load
Voltage U21, U32, U13, V1, V2, V3 on load
Width144 mm
AlarmStep power loss ( 6 A CT) / Action: message and alarm contact
Hunting (unstable regulation) / Action: message and alarm contact + step blocked
Low current ( 130 % I1) / Action: message and alarm contact + step switched off
Overtemperature (50°C) / Action: message and alarm contact + step switched off
Overtemperature (30°C) / Action: fan switch
Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped
Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off
Overcompensation / Action: message and alarm contact

OTHERS

CertificationsCE
EAC
NRTL
CNRTL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider Power Factor Controller VPL12N”

There are no reviews yet.

wpChatIcon
    wpChatIcon

    Select at least 2 products
    to compare